Protótipo de almofada para aferição da pressão e temperatura em áreas anatômicas de risco para desenvolvimento de lesão por pressão
dc.contributor.advisor | Lima, Mário Oliveira | |
dc.contributor.author | Rocha, Francisca Cecília Viana | |
dc.contributor.coadvisor | Mendes, Alessandro Corrêa | |
dc.contributor.event2 | São José dos Campos | |
dc.contributor.referee | Madeira, Maria Zelia de Araujo | |
dc.contributor.referee | Martins, Patrícia Sardinha Leonardo Lopes | |
dc.contributor.referee | Arisawa, Emília Angela Loschiavo | |
dc.date.accessioned | 2024-11-22T17:50:02Z | |
dc.date.available | 2024-11-22T17:50:02Z | |
dc.date.issued | 2022-06-07 | |
dc.description.abstract | A lesão por pressão(LP) configura-se como resultado da pressão exercida pelo corpo sobre a superfície anatômica em que o indivíduo se encontra. Apesar das mais diversas estratégias para a sua prevenção, a incidência de lesão por pressão ainda é alta em todo o mundo. Por conseguinte, pesquisadores estão se voltando para uma nova tecnologia de mapeamento de pressão e temperatura para auxiliar as estratégias de prevenção das lesões por pressão. Portanto, o presente estudo tem como objetivo desenvolver e validar protótipo de almofada para aferição da pressão e da temperatura em áreas anatômicas de risco para desenvolvimento de lesão por pressão. Trata-se de um estudo experimental descritivo dividido em três etapas: desenvolvimento do software, criação do protótipo e validação do protótipo. A primeira e a segunda etapas foram desenvolvidas em laboratório, enquanto a terceira etapa foi realizada em um hospital público no Nordeste do Piauí. Etapa I: O software foi sintetizado em linhas de programação, utilizando a linguagem C para escrita do software. O hardware consiste no circuito eletrônico, descrito como uma placa com componentes eletrônicos. Foi desenvolvido um programa para controlar o passo-a-passo do hardware. Etapa II: O protótipo apresenta sensores de temperatura e pressão, microprocessador, driver; compressor de ar; bateria de 12V; e almofada inflável e impermeável. Etapa III: Participaram do estudo um adulto saudável, sem risco para o desenvolvimento de LP, sexo masculino, 33 anos de idade, 74 kg, 1,70 cm e 25,31 IMC. O segundo participante era um adulto com alto risco para o desenvolvimento de LP, 11 na escala de Braden, sexo masculino, 55 anos de idade, 75 kg, 1,74 cm e 25,31 IMC.O teste com o participante saudável revelou pressão de interface máxima, registrada na região occipital, porém, a média de pressão de interface foi maior na região sacral. No tocante a temperatura corporal a média, de maior valor foi identificada na região sacral (34,92ºC). Por sua vez, o teste com o paciente na UTI, a pressão de interface máxima, foi registrada na região do calcâneo esquerdo. A pressão de interface média, também foi encontrada na região sacral. A respeito da temperatura corporal média, o valor máximo, também, foi detectado na região sacral (35,31ºC). Ao comparar os dados de pressão e temperatura em todas as áreas anatômicas, observou-se que estão diretamente proporcionais nos dois participantes, quando uma aumenta, a outra também aumenta. Conclui-se que o protótipo da almofada com sensor para medir a pressão de interface e a temperatura em áreas anatômicas de risco para o desenvolvimento de lesão por pressão teve o potencial de fornecer medidas objetivas que podem atuar como substitutos para orientar as áreas onde a pressão e a temperatura estiverem alteradas para que sejam adotadas medidas de alívio em locais específicos e, assim, prevenir lesão por pressão de forma individualizada a cada paciente. | |
dc.description.abstract2 | Pressure Injury (LP) is a result of the pressure exerted by the body on the anatomical surface on which the individual is. Despite the most diverse strategies for its prevention, the incidence of pressure injuries is still high worldwide. Therefore, researchers are turning to new pressure and temperature mapping technology to aid pressure injury prevention strategies. Therefore, the present study aims to develop and validate a prototype pad for measuring pressure and temperature in anatomical areas at risk for pressure injury development. This is a descriptive experimental study divided into three stages: software development, prototype creation and prototype validation. The first and second stages were developed in the laboratory, while the third stage was carried out in a public hospital in the Northeast of Piauí. Step I: The software was synthesized in programming lines, using the C language to write the software. The hardware consists of the electronic circuit, described as a board with electronic components. A program was developed to control the hardware step-by- step. Stage II: The prototype presents temperature and pressure sensors, microprocessor, driver; air compressor; 12V battery; and inflatable and waterproof cushion. Stage III: A healthy adult, without risk for the development of PI, participated in the study, male, 33 years old, 74 kg, 1.70 cm and 25.31 BMI. The second participant was an adult at high risk for the development of PI, 11 on the Braden scale, male, 55 years of age, 75 kg, 1.74 cm and 25.31 BMI. The test with the healthy participant revealed pressure maximum interface pressure, recorded in the occipital region, however, the average interface pressure was higher in the sacral region. With regard to body temperature, the highest value was identified in the sacral region (34.92ºC). In turn, the test with the patient in the ICU, the maximum interface pressure, was recorded in the region of the left calcaneus. The mean interface pressure was also found in the sacral region. Regarding the mean body temperature, the maximum value was also detected in the sacral region (35.31ºC). When comparing pressure and temperature data in all anatomical areas, it was observed that they are directly proportional in the two participants, when one increases, the other also increases. It is concluded that the prototype of the sensor pad to measure interface pressure and temperature in anatomic areas at risk for the development of pressure injuries had the potential to provide objective measures that can act as surrogates to guide the areas where pressure and temperature are altered so that relief measures are taken in specific places and, thus, to prevent pressure injuries in an individualized way for each patient. | |
dc.description.physical | 95 f. | |
dc.format.mimetype | ||
dc.identifier.affiliation | Universidade do Vale do Paraíba | |
dc.identifier.bibliographicCitation2 | ROCHA, Francisca Cecília Viana. Protótipo de almofada para aferição da pressão e temperatura em áreas anatômicas de risco para desenvolvimento de lesão por pressão. São José dos Campos, 2022. 95 f. Tese (Doutorado em Engenharia Biomédica) - Universidade do Vale do Paraíba, Instituto de Pesquisa e Desenvolvimento, São José dos Campos, 2022 | |
dc.identifier.uri | https://repositorio.univap.br/handle/123456789/424 | |
dc.language.iso | pt_BR | |
dc.publisher.country | Brasil | |
dc.publisher.initials | UNIVAP | |
dc.publisher.institution | Universidade do Vale do Paraíba | |
dc.publisher.program | doutorado em Engenharia Biomédica | |
dc.publisher.spatial | São José dos Campos | |
dc.subject.keyword | Lesão por pressão | |
dc.title | Protótipo de almofada para aferição da pressão e temperatura em áreas anatômicas de risco para desenvolvimento de lesão por pressão | |
dc.title.alternative | Cushion prototype for measuring pressure and temperature in anatomical areas at risk for development of pressure injury | |
dc.type | Tese |