Efeito da fotobiomodulação na fadiga muscular de bíceps braquial em indivíduos espásticos
dc.contributor.advisor | Lima, Mário Oliveira | |
dc.contributor.author | Spinelli, Bruna Moreira de Oliveira | |
dc.contributor.coadvisor | Martins, Rodrigo Álvaro Brandão Lopes | |
dc.contributor.event2 | São José dos Campos | |
dc.contributor.referee | Simioni, Andreza Ribeiro | |
dc.contributor.referee | Lucareli, Paulo Roberto Garcia | |
dc.date.accessioned | 2024-12-09T17:27:13Z | |
dc.date.available | 2024-12-09T17:27:13Z | |
dc.date.issued | 2021-05-06 | |
dc.description.abstract | A espasticidade pode ser desencadeada pelo Acidente Vascular Encefálico (AVE), doença que acomete o sistema nervoso central (SNC). As alterações neuromusculares e bioquímicas geradas pela espasticidade tornam o músculo mais propenso à fadiga. Isso influencia negativamente nas atividades de vida diária e na qualidade de vida do paciente. Pesquisas tem utilizado a fotobiomodulação como recurso para melhorar a performance muscular, no entanto, pouco se sabe sobre seu efeito na fadiga muscular espástica. Desse modo, o objetivo desse trabalho é avaliar a atividade mioelétrica e a força isométrica máxima do músculo bíceps braquial espástico após a aplicação da fotobiomodulação, além de avaliar a intensidade dolorosa e a intensidade de esforço antes, logo após o protocolo de força, e depois de 24 horas e 48 horas. Trata-se de um estudo clínico, cego, cruzado, randomizado, no qual foram selecionados 7 indivíduos que apresentavam espasticidade em membro superior, com idade média de 51±14,16 anos. Os voluntários foram divididos em 3 grupos: controle, fotobiomodulação (PBMT) e placebo; de forma que todos compuseram em algum momento todos os grupos. Foi aplicado a PBMT (diodo laser, 808nm, 100mW, 3J/ponto, 9 pontos) no músculo bíceps braquial antes do protocolo de força. O protocolo consistiu em 3 contrações voluntárias máxima isométrica (CVMI) de bíceps braquial por 50 segundos seguido de 50 segundos de repouso a cada contração. Durante a CVMI, foi mensurada a força e sinal eletromiográfico. Foi observado aumento da força (p = 0,0025) e da atividade elétrica muscular (p = 1,91-6) no PBMT, porém o valor da frequência média da eletromiografia se mostrou superior no grupo placebo (p = 1,91-5). A avaliação da dor mostrou que apenas o grupo PBMT apresentou dor imediata em repouso e em movimento (p ? 0,05), não houve realce da dor após 24 e 48 horas para ambos os grupos. Segundo a avaliação de esforço, ambos os grupos não apresentaram exaustão (p ? 0,05). Com esses achados pode-se concluir que a fotobiomodulação contribuiu para o aumento da força e da ativação elétrica muscular, também desencadeou maior sensação dolorosa no grupo PBMT. | |
dc.description.abstract2 | The spasticity can be triggered by the stroke, disease which affects the Central Nervous System (CNS). The biochemical and neuromuscular alterations generated by the spasticity make the muscle proner to fatigue. This negatively influences the activities of daily living and the patient's quality of life. Many researches have utilized photobiomodulation as resource to improve muscle performance, however, little is known about its effect on spastic muscle fatigue. Thus, this work’s objetive is to analyze the isometric maximum strength behavior of the spastic brachial biceps and myoelectric activity after photobiomodulation, in addition to assessing painful intensity and intensity of effort before, just after the strength protocol, and after 24 hours and 48 hours. It is about a clinic study, blind, crossover, randomized. In which 7 individuals were selected who had spasticity in the upper limb. with an average age of 51 ± 14.16 years. They were divided into 3 groups: control, photobiomodulation (PBMT) and placebo; so that everyone composed, at some point, all the groups. It was applied to PBMT (laser diode, 808nm, 100mW, 3J / point, 9 points) in the brachial biceps before the strenght protocol. The protocol consisted of 3 voluntary maximum isometric contractions (VMIC) of brachial biceps for 50 seconds followed by 50 seconds of rest at each contraction. During the VMIC, the electromyographic signal and strength were measured. An increase in strength (p = 0,0025) and myoelectric activity (p = 1,91-6) was observed in PBMT, but the mean values were higher in the placebo group (p = 1,91-5). The pain assessment showed that only the PBMT group presented immediate pain at rest and in movement (p ? 0.05), there was no donor enhancement after24 and 48 hours for both groups. According to the effort evaluation, both groups were not exhausted (p ? 0.05). With these findings, it can be concluded that photobiomodulation contributed to the increase in muscle strength and electrical activation, also triggered greater painful sensation in the PBMT group. | |
dc.description.physical | 65 f. | |
dc.format.mimetype | ||
dc.identifier.affiliation | Universidade do Vale do Paraíba | |
dc.identifier.bibliographicCitation2 | SPINELLI, Bruna Moreira de Oliveira. Efeito da fotobiomodulação na fadiga muscular de bíceps braquial em indivíduos espásticos. São José dos Campos, 2021. 65 f. Dissertação (Mestrado em Engenharia Biomédica) - Universidade do Vale do Paraíba, Instituto de Pesquisa e Desenvolvimento, São José dos Campos, 2021. | |
dc.identifier.uri | https://repositorio.univap.br/handle/123456789/460 | |
dc.language.iso | pt_BR | |
dc.publisher.country | Brasil | |
dc.publisher.initials | UNIVAP | |
dc.publisher.institution | Universidade do Vale do Paraíba | |
dc.publisher.program | Mestrado em Engenharia Biomédica | |
dc.publisher.spatial | São José dos Campos | |
dc.subject.keyword | Fotobiomodulação | |
dc.subject.keyword | Fadiga muscular | |
dc.subject.keyword | Eletromiografia | |
dc.title | Efeito da fotobiomodulação na fadiga muscular de bíceps braquial em indivíduos espásticos | |
dc.title.alternative | Effect of photobiomodulation on muscle fatigue in biceps brachii of spastic individuals | |
dc.type | Dissertação | |
dc.type.masterDegree | Acadêmico |