Perfil da temperatura induzida pela radiofrequência em tecidos biológicos ex vivo aferido pela termografia infravermelha computadorizada
dc.contributor.advisor | Martins, Rodrigo Álvaro Brandão Lopes | |
dc.contributor.author | Conceição, Francileine Rodrigues da | |
dc.contributor.coadvisor | Arisawa, Emília Angela Loschiavo | |
dc.contributor.event2 | São José dos Campos | |
dc.contributor.referee | Lima, Mário Oliveira | |
dc.contributor.referee | Marcos, Rodrigo Labat | |
dc.date.accessioned | 2025-01-27T14:22:25Z | |
dc.date.available | 2025-01-27T14:22:25Z | |
dc.date.issued | 2020 | |
dc.description.abstract | A radiofrequência (RF) é um recurso utilizado no tratamento da flacidez e gordura localizada, sendo considerada eficaz e de baixo custo. A termografia infravermelha computadorizada (TIC) tem se demonstrado como uma ferramenta não invasiva de diagnóstico eficaz, que permite o monitoramento em tempo real das variações de temperatura (T) nos tecidos biológicos. Buscando estudar os efeitos da RF nos tecidos, este estudo tem por objetivo avaliar variações na massa, espessura e validar a TIC para detecção de alterações de T, antes e após aplicação da RF, em tecidos biológicos ex vivo. Foram utlizados17 corpos de prova (Susscrofa domesticus), peso entre 0,260 e0,646Kg, alocados em dois grupos: G1-potência de 60 W, seis animais, e G2-potência de 120 W, 11 animais. As aplicações de RF foram realizadas com aparelho de RF monopolar em 27,12 MHz, por 5 minutos, em uma área de 100 cm². Foram coletados dados referentes à massa, espessura e aferidas as temperaturas superficial e lateral com auxílio de termômetro infravermelho(TI), enquanto o perfil de profundidade térmica foi avaliado pela TIC (ThermaCam S65HS, FLIR ®) antes e após o tratamento com RF. Os dados coletados da TIC foram analisados pelo software ThermaCAM Researcher Pro 2.8 SR-1. Os demais resultados foram analisados utilizando o programa BioStat 5.3. Os resultados demonstraram variação média do peso dos corpos de prova antes e após a RF de 1,83±1,34g (p= 0,02) em G1 e 2,36±1,29g(p<0,0001) em G2; não houve variação da espessura em nenhum dos grupos estudados. As temperaturas aferidas com TI na região superficial dos corpos de prova apresentaram aumento de 13,6±6,01º C (p= 0,0039) em G1 e de 32,82±15,77º C(p<0,0001) emG2, após a RF. As imagens obtidas pelo TIC, após a RF, demonstraram que as áreas com maior T também se localizavam na superfície, com aumento de 12,15º C em G1 (p= 0,0083) e 22,91º C em G2 (p= 0,0033). Além disso, a avaliação dos termogramas demonstrou tendência de queda das temperaturas nas camadas mais profundas dos corpos de prova. Os resultados deste estudo pioneiro permitem concluir que tanto a TIC quanto o termômetro infravermelho demonstraram elevação da temperatura nos corpos de prova após a aplicação da RF, principalmente na região superficial das amostras estudadas. Alerta-se, ainda, que quando utilizada a potência de 120 W, detectou-se drástico aumento de temperatura na epiderme, que pode causar desconforto ou até mesmo queimaduras ao paciente. Assim, a TIC permite avaliar a profundidade do aquecimento induzida pela aplicação da RF em tecidos ex vivo, com valores semelhantes ao obtidos com o termômetro infravermelho, essa aplicabilidade pode ser utilizada para o monitoramento de procedimentos clínicos na área da estética. | |
dc.description.abstract2 | adiofrequency (RF) is a resource used in the treatment of sagging and localized fat, being considered effective and low cost. Computerized infrared thermography (ICT) has been shown to be an effective non-invasive diagnostic tool that allows real-time monitoring of temperature variations (T) in biological tissues. Seeking to investigate the effects of RF on tissues, this study aims to evaluate variations in mass, thickness and to validate ICT for detecting T changes, before and after RF application, in ex vivo biological tissues. Seventeen specimens (Susscrofa domesticus), weighing between 0.260 and 0.646 kg, were used in two groups: G1-60 W power, six animals, and G2 -120 W power, 11 animals. RF applications were performed with a monopolar RF device at 27.12 MHz, for 5 minutes, in an area of 100 cm².Mass and thickness data were collected, and the surface and side temperatures were measured with the aid of an infrared thermometer (TI), while the thermal depth profile was assessed by ICT (ThermaCam S65HS, FLIR ®) before and after treatment with RF. The data collected from the ICT were analyzed using the ThermaCAM Researcher Pro 2.8 SR-1 software. The other results were analyzed using the BioStat 5.3 program. The results showed an average variation in the weight of the specimens before and after the RF of 1.83 ± 1.34g (p = 0.02) on G1 and 2.36 ± 1.29g (p <0.0001) on G2; there was no variation in thickness in any of the groups studied. The temperatures measured with TI on the surface of the specimens increased by 13.6 ± 6.01º C (p = 0.0039) in G1 and 32.82 ± 15.77º C (p <0.0001) in G2, after the RF. The images obtained by the ICT, after the RF, showed that the areas with the highest T were also located on the surface, with an increase of 12.15º C in G1 (p = 0.0083) and 22.91º C in G2 (p = 0.0033). The results of this pioneering study allow us to conclude that both the ICT and the infrared thermometer showed an increase in temperature in the specimens after RF, mainly in the superficial region of the studied samples. We also warn that RF at 120 W power induced a drastic increase in temperature in the epidermis, which can cause discomfort or even burns to the patient.Furthermore, the evaluation of thermograms showed a tendency for temperatures to drop in the deeper layers of the specimens. The results of this pioneering study allow us to conclude that the ICT allows to evaluate the depth of the RF induced heating in ex vivotissues, with values similar to those obtained with the infrared thermometer. This applicability can be used to monitor clinical procedures in the field of aesthetics | |
dc.description.physical | 64 f. | |
dc.format.mimetype | ||
dc.identifier.affiliation | Universidade do Vale do Paraíba | |
dc.identifier.bibliographicCitation2 | CONCEIÇÃO, Francileine Rodrigues da. Perfil da temperatura induzida pela radiofrequência em tecidos biológicos ex vivo aferido pela termografia infravermelha computadorizada. São José dos Campos, 2020. 65 f. Dissertação (Mestrado em Engenharia Biomédica) - Universidade do Vale do Paraíba, Instituto de Pesquisa e Desenvolvimento, São José dos Campos, 2020. | |
dc.identifier.uri | https://repositorio.univap.br/handle/123456789/520 | |
dc.language.iso | pt_BR | |
dc.publisher.country | Brasil | |
dc.publisher.initials | UNIVAP | |
dc.publisher.institution | Universidade do Vale do Paraíba | |
dc.publisher.program | Mestrado em Engenharia Biomédica | |
dc.publisher.spatial | São José dos Campos | |
dc.subject.keyword | Radiofrequência | |
dc.subject.keyword | Termografia Infravermelha | |
dc.subject.keyword | Rejuvenescimento | |
dc.title | Perfil da temperatura induzida pela radiofrequência em tecidos biológicos ex vivo aferido pela termografia infravermelha computadorizada | |
dc.title.alternative | Profile of temperature induced by radiofrequency inex vivo biological tissues affected by thermography computerized infrared | |
dc.type | Dissertação | |
dc.type.masterDegree | Acadêmico |