Efeito da membrana de polihidroxibutirato à base de norbixina associada à terapia led de baixa intensidade no processo de reparo tendíneo pós-tenotomia: estudo in vivo

dc.contributor.advisorNicolau, Renata Amadei
dc.contributor.authorNascimento, Lízia Daniela e Silva
dc.contributor.event2São José dos Campos
dc.contributor.refereeArisawa, Emília Angela Loschiavo
dc.contributor.refereeLima, Mário Oliveira
dc.contributor.refereeOliveira, Luciane Dias de
dc.contributor.refereeCunha, Tatiana de Sousa da
dc.date.accessioned2025-01-27T15:28:20Z
dc.date.available2025-01-27T15:28:20Z
dc.date.issued2020-03-30
dc.description.abstractA ruptura do tendão calcâneo apresenta uma elevada incidência, podendo resultar em redução severa da funcionalidade do tornozelo. O tratamento cirúrgico dessa lesão possibilita tanto a reparação como menor índice de recidiva da ruptura. Diversos estudos apontam o sucesso da terapia com LED no reparo da tenotomia, contudo sem a associação com membranas biológicas. O presente estudo teve como objetivo investigar o efeito da membrana de polihidroxibutirato (PHB) à base de norbixina associada à terapia com LED no reparo tendíneo após tenotomia calcânea em ratos. Foram utilizados 60 ratos machos, com aproximadamente 10 semanas de vida e 250g, divididos em 12 grupos, sendo 4 grupos: LC1 (Lesionado-controle), MNo1 (Membrana), LED1 (LED) e MNo+LED1 (Membrana+LED) eutanasiados 7 dias após a cirurgia, 4 grupos: LC2, MNo2, LED2 e MNo+L2 eutanasiados com 14 dias de PO e 4 grupos: LC3, MNo3, LED3 e MNo+LED3 eutanasiados 21 dias após o início do experimento. Nos grupos MNo e MNo+LED foram colados fragmentos de membranas no local da transecção tendínea, enquanto os grupos LC e LED não receberam a membrana. A terapia com LED foi realizada em um único ponto nos grupos LED e MNo+LED com a dosagem de 6 J/cm2 a cada 24 horas, durante 214,3 segundos por vez. No final dos experimentos os tendões foram removidos para análise histológica utilizando os programas Image-J® e Image J Pro-plus. Este estudo apresentou redução significativa de células inflamatórias no grupo MNo+LED em relação ao grupo LC (p<0,0001) nos três períodos de tempo. Foi verificada também proliferação significativa de fibroblastos no grupo MNo+LED em relação ao LC (p<0,0001) aos 7 e 14 dias, bem como um expressivo aumento de fibroblastos no grupo LED em todos os tempos experimentais. Observou-se também a formação do colágeno tipo I com resultados estatisticamente significativos nos grupos MNo1 (p=0,0133), MNo+LED1 (p=0,0002) e MNo2 (p=0,0210) quando comparados aos respectivos LC. A concentração de colágeno tipo III foi maior em todos os grupos aos 7, 14 e 21 dias do estudo. Conclui-se, assim, que O emprego da membrana de PHB à base de norbixina associada à terapia LED de baixa intensidade no tratamento de tenotomia total calcânea de ratos reduziu os níveis de infiltrado inflamatório na lesão, favoreceu a proliferação de fibroblastos nas duas primeiras semanas, porém não otimizou a formação de colágeno tipo I no estágio esperado do processo de reparação, indicando que houve pouca efetividade no uso simultâneo dos dois elementos terapêuticos.
dc.description.abstract2The rupture of the calcaneus tendon has a high incidence and may result in severe reduction of ankle functionality. The surgical treatment of this lesion allows both repair and reduced recurrence rates of the rupture. Several studies point to the success of LED therapy in tenotomy repair, but without association with biological membranes. This study aimed to investigate the effect of norbixin-based poly(hydroxybutyrate) (PHB) membrane associated with LED therapy in the repair of calcaneal tendon ruptures in tenotomized rats. Were used 60 male rats, approximately 10 weeks old and 250g, divided into 12 groups, 4 groups: LC1 (Control Injury), MNo1(Membrane), LED1(LED) and MNo+LED1(Membrane+LED) were eutanasiated 7 days after surgery, 4 other groups: LC2, MNo2, LED2 and MNo+LED2 were eutanasiated 14 days postoperatively and 4 other groups: LC3, MNo3, LED3 and MNo+LED3 were eutanasiated 21 days after the start of the experiment. Membrane fragments were glued at the site of the tendinous transection in the MNo and MNo+LED groups, while the LC and LED groups did not receive the membrane. The LED therapy was performed at a single point in the LED and MNo+LED groups using a dosage of 6 J/cm2 every 24 hours for 214.3 seconds at a time. At the end of the experiments, the tendons were removed for histological analysis using the Image-J® and Image J Pro-plus programs. This study showed significant reduction of inflammatory cells in the MNo+LED group compared to the LC group (p<0,0001) in the three time periods. Significant proliferation of fibroblasts in the MNo+LED group was also observed in relation to LC (p<0,0001) at 7 and 14 days, as well as a significant increase of fibroblasts in the LED group at all experimental times. Type I collagen formation was also observed with statistically significant results in groups MNo1 (p=0,0133), MNo+LED1 (p=0,0002) and MNo2 (p=0,0210) when compared to the respective LC. The concentration of collagen type III was higher in all groups at 7, 14 and 21 days of the study. It is concluded that the use of norbixin-based PHB membrane associated with low intensity LED therapy in the treatment of total calcaneal tenotomy of rats reduced the levels of inflammatory infiltration in the lesion, favored the proliferation of fibroblasts in the first two weeks, but did not optimize the formation of type I collagen in the expected stage of the repair process, indicating that there was little effectiveness in the simultaneous use of the two therapeutic elements.
dc.description.physical77 f.
dc.format.gradesBolsa concedida pela Fundação Vale Paraibana de Ensino.
dc.format.mimetypePDF
dc.identifier.affiliationUniversidade Estadual do Piauí
dc.identifier.bibliographicCitation2NASCIMENTO, Lízia Daniela e Silva. Efeito da membrana de polihidroxibutirato à base de norbixina associada à terapia led de baixa intensidade no processo de reparo tendíneo pós-tenotomia: estudo in vivo. São José dos Campos, 2020. 77 f. Tese (Doutorado em Engenharia Biomédica) - Universidade do Vale do Paraíba, Instituto de Pesquisa e Desenvolvimento, São José dos Campos, 2020.
dc.identifier.urihttps://repositorio.univap.br/handle/123456789/523
dc.language.isopt_BR
dc.publisher.countryBrasil
dc.publisher.initialsUNIVAP
dc.publisher.institutionUniversidade do Vale do Paraíba
dc.publisher.programdoutorado em Engenharia Biomédica
dc.publisher.spatialSão José dos Campos
dc.subject.keywordPolihidroxibutirato
dc.subject.keywordTerapia com LED
dc.subject.keywordTendão calcâneo
dc.titleEfeito da membrana de polihidroxibutirato à base de norbixina associada à terapia led de baixa intensidade no processo de reparo tendíneo pós-tenotomia: estudo in vivo
dc.title.alternativeEffect of norbixin-based polyhydroxybutyrate membrane associated with low-intensity led therapy in the post-tenotomy process of tendon repair - in vivo study
dc.typeTese

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Tese Lizia.pdf
Tamanho:
5.46 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:

Coleções