Sistema microprocessado para avaliação de amplitude de movimento e da força muscular, do conjunto osteomioarticular, com a utilização de acelerômetro e giroscópio
dc.contributor.advisor | Lima, Mário Oliveira | |
dc.contributor.author | Lemos, Sergio Luiz | |
dc.contributor.event2 | São José dos Campos | |
dc.contributor.referee | Arisawa, Emília Angela Loschiavo | |
dc.contributor.referee | Silva, Alessandro Pereira | |
dc.date.accessioned | 2025-01-24T18:01:42Z | |
dc.date.available | 2025-01-24T18:01:42Z | |
dc.date.issued | 2020-10-05 | |
dc.description.abstract | Introdução: A postura estável de um indivíduo é o resultado de um equilíbrio de forças concorrentes, no conjunto musculoesquelético, onde os músculos tem a função de gerar as forças necessárias para a estabilização esquelética. A condição de movimento com o domínio da capacidade funcional, é um fator importante na qualidade de vida, estado geral de saúde, vitalidade e saúde mental. Desta forma, a amplitude de movimento (ADM) e a força muscular são dois fatores muito relevantes para avaliação do conjunto musculoesquelético de um indivíduo, permitindo diagnóstico diferencial, prognóstico e tratamento de distúrbios musculoesqueléticos e neuromusculares. Objetivo: Desenvolver e validar um sistema para medição de ADM e forçamuscular, utilizando sensores inerciais, que realizem a aquisição de dados e permitam analisar o desempenho de movimentos no conjunto musculoesquelético. Métodos: Foram colocadossensores em cinco indivíduos hígidos, ambos os gêneros, onde os mesmos serão submetidos a sériesde movimentos, de flexão de cotovelo e joelho no dinamômetro isocinético Biodex System 3TM. As séries para ensaios de ADM foram sem carga, e as séries para ensaios de força foram com carga. A validação do sistema foi realizadacom a análise e comparação com os dados obtidos no dinamômetro isocinético. Resultados: O sistemadesenvolvidomostrou resultados confiáveis para a medida angular, validando o estudo. Com relação a força, este estudo não tem o intuito de fornecer dados da força como sendo absolutos,uma vez que a mesma é calculada a partir dos dados de variação angular do movimento. Omodeloutilizado permite obter dados quantitativos para a comparação em um mesmo indivíduo ao longo do tempo.Estudos futuros podem ser conduzidos para análise do melhor modo de uso ou representação deste modelo, ou mesmo, do seu aprimoramento.Conclusão: O sistema desenvolvido é um protótipo, mas tem a possibilidade de se tornaruma boa ferramenta para a área defisioterapia,abrindo também oportunidades de estudos na área da reabilitação sensório motora. | |
dc.description.abstract2 | Introduction: The stable posture of an individual is the result of a balance of competing forces, in the musculoskeletal set, where the muscles have the function of generating the forces necessary for skeletal stabilization. The condition of movement with the mastery of functional capacity is an important factor in quality of life, general health status, vitality and mental health. Thus, range of motion (ROM) and muscle strength are two very relevant factors for the evaluation of an individual's musculoskeletal complex, allowing differential diagnosis, prognosis and treatment of musculoskeletal and neuromuscular disorders. Objective: To develop and validate a system for measuring ROMand muscular force, using inertial sensors, which perform dataacquisition and allow analyzing the performance of movements in the musculoskeletal set. Methods: The sensors wereplaced in fivehealthy individuals, both sexes, andweresubmitted to a series of movements, elbow and knee flexion in the Biodex System 3TMisokinetic dynamometer. The series for ROMtesting wereunloaded, and the series for muscular force tests wereloaded. The validation of the system tookplace with the analysis and comparison with the data obtained in the isokinetic dynamometerResults: The system showed reliable results for the angular measurement, validating the study. With regard to strength, this study does not intend to provide force data as being absolute, since it is calculated from the angular variation of motion data. The model used allows obtaining quantitative data for comparison in the same individual over time. Future studies can be conducted to analyze the best way of using or representing this model, or even, its improvement. Conclusion: The developed system is a prototype, but it has the possibility of becoming a good tool for the physiotherapy area, also opening up opportunities for studies in the area of sensory motor rehabilitation. | |
dc.description.physical | 95 f. | |
dc.format.mimetype | ||
dc.identifier.affiliation | Universidade do Vale do Paraíba | |
dc.identifier.bibliographicCitation2 | LEMOS, Sergio Luiz. Sistema microprocessado para avaliação de amplitude de movimento e da força muscular, do conjunto osteomioarticular, com a utilização de acelerômetro e giroscópio. São José dos Campos, 2020. 95 f. Dissertação (Mestrado em Engenharia Biomédica) - Universidade do Vale do Paraíba, Instituto de Pesquisa e Desenvolvimento, São José dos Campos, 2020. | |
dc.identifier.uri | https://repositorio.univap.br/handle/123456789/518 | |
dc.language.iso | pt_BR | |
dc.publisher.country | Brasil | |
dc.publisher.initials | UNIVAP | |
dc.publisher.institution | Universidade do Vale do Paraíba | |
dc.publisher.program | Mestrado em Engenharia Biomédica | |
dc.publisher.spatial | São José dos Campos | |
dc.subject.keyword | Reabilitação | |
dc.subject.keyword | Osteomioarticular | |
dc.subject.keyword | Goniometria | |
dc.title | Sistema microprocessado para avaliação de amplitude de movimento e da força muscular, do conjunto osteomioarticular, com a utilização de acelerômetro e giroscópio | |
dc.title.alternative | Microprocessed system for assessment of the range of movement and muscular strength of the musculoskeletal system using accelerometer and gyroscope | |
dc.type | Dissertação | |
dc.type.masterDegree | Acadêmico |